High-Performance Dehumidifier with Air Purifier DM-A212

  • Powerful Dehumidification

    Capable of extracting up to 12 liters of moisture per day (at 27°C, 60% humidity), effectively reducing indoor humidity and preventing dampness.

  • تشغيل هادئ

    Operates at a low noise level of 48dB, ensuring a peaceful environment suitable for bedrooms, living rooms, and offices.

  • Efficient Water Management

    Equipped with a 3.7L water tank و tank-full auto-off indicator, preventing overflow and enabling hassle-free operation. Optional continuous water drainage adds convenience for extended use.

  • Smart Humidity Control

    Adjustable humidity settings from 40% to 70% RH, with an intuitive digital display showing real-time humidity levels.

طلب عرض أسعار

وصف المنتج

high performance dehumidifier dm a212
  • Energy-Efficient Performance: Rated at 194W, optimized for consistent performance while conserving energy.
  • Portable and User-Friendly: Lightweight design with a handle و wheels for easy movement.
  • Smart Connectivity Options: Optional TUYA Wi-Fi control for remote operation and monitoring.
  • Multi-Functionality الميزات auto-swing airflow for wide coverage, auto-defrostو inner drying to prevent mold and maintain device hygiene.
high performance dehumidifier dm a212

The DM-A212 Dehumidifier combines powerful performance, smart controls, and enhanced air purification to create a healthier and more comfortable living space. Its compact design and advanced features make it an ideal choice for modern homes and offices. Let me know if you need further refinements!

high performance dehumidifier dm a212

المواصفات

Power supply
110V/60Hz
Dehumidification Capacity
12L/day (27°C, 60%)
الطاقة المقدرة
194W (27°C, 60%)
سعة خزان المياه
3.7L
الضوضاء
< 48dB(A)
Speed
3
Humidity Range
Adjustable from 40%–70% RH
Refrigerant
R134a
Air Flow
180m³ / h (High speed)
المؤقِّت
1-12H
الأبعاد
376 × 271 × 578 mm
الوزن
14.5 kg
التصفية
H11 Hepa Filter
Fuction
PM 2.5 sensor, Auto-Defrost, Child Lock, Inner Dry: Prevent mold, Tank full indicator with AUTO-OFF, Digital 88 Display
اختياري
Water Drainage, TUYA Wi-Fi

تنزيلات المستندات ذات الصلة

لا توجد تنزيلات متاحة.

مقالات ذات صلة بـ High-Performance Dehumidifier with Air Purifier DM-A212

لا توجد مقالات ذات صلة متاحة.

لماذا تختار أجهزة تنقية الهواء التي نقدمها؟

High-Performance Air Purification
Advanced Filtration Options
99.91.9% البكتيرية
معدل الإزالة
ارتفاع CADR
(معدل توصيل الهواء النظيف)
H13/H14 HEPA Filtration Options
Optional 270–280 nm UVC Module
H14 H13 extended filter life
lifespan HEPA filters
Third-Party Tested Filtration Performance

أفضل 3 مصنعي أجهزة تنقية الهواء OEM/ODM في الصين

وضع العلامات الخاصة لأجهزة تنقية الهواء ذات العلامات التجارية لعقود من الزمن

تقدم شركة HisoAir خدمات وضع العلامات الخاصة على أجهزة تنقية الهواء للعملاء الذين قاموا بالفعل بمراجعة تصميم ومواصفات أجهزة تنقية الهواء من HisoAir ووافقوا عليها. بمجرد توقيع الاتفاقية، سيتم وضع علامة باسم العميل على المنتجات المختارة.

أجهزة تنقية الهواء من OEM من البداية إلى النهاية

تقدم شركة HisoAir خدمات تنقية الهواء من مصنعي المعدات الأصلية للشركاء الذين لديهم المواصفات اللازمة في المنتج. تقدم شركة HisoAir خدمات البحث والتصميم والهندسة والنماذج أو التعديلات والاختبار والإنتاج بكميات كبيرة بناءً على التصميم النهائي للعميل.

شعار شركة 3M 3M باللون الأحمر.
شعار الناقل
شعار هاير
شعار ألين - موثوق به في مجال تنقية الهواء
شعار tcl 0
شعار هانيويل - الشركة الرائدة في مجال حلول تنقية الهواء والترشيح
شعار LG - شركة مبتكرة في الأجهزة المنزلية الذكية وحلول تنقية الهواء
شعار فيليبس - شركة رائدة في مجال التكنولوجيا الصحية وحلول تنقية الهواء

موثوق بها من قبل علامات تجارية عالمية شهيرة

مع أكثر من 20 عاماً من الخبرة، نحن متخصصون في تقديم حلول IAQ التي تتكامل بسلاسة مع احتياجات العلامات التجارية الأكثر شهرة في العالم. كن شريكاً معنا لتحقيق أداء استثنائي مصمم خصيصاً لسوقك

الشهادات

" لقد وجدت موقع hisoair الإلكتروني من جوجل، ولأكون صادقًا، لم أكن متأكدًا من موثوقيتهم في البداية، لكنهم أكملوا متطلبات مشروعي في شهر ونصف. وعندما تطلب المشروع الإضافة العاجلة لمستشعر ثاني أكسيد الكربون، أنجزوا عينة جديدة في غضون أسبوع، مما يجعلهم أكثر الشركات المصنعة احترافية وتركيزًا على العملاء الذين تعاملت معهم على الإطلاق "
TMS 1
توماس
مورد حكومي من ألمانيا
" نعلم جميعًا أن كوفيد كان كارثة رهيبة للعالم بأسره، خاصة بالنسبة للهند، لقد اشتريت جهاز تنقية الهواء من هيسو اير، لقد كان هذا مفيدًا جدًا لي ولمكتبي ومنزلي وعائلتي وأصدقائي، لقد عملت مع ألوين على مدار السنوات السبع الماضية، وهو من هيسو اير، يمكنني أن أؤكد أنه شخص موثوق به للغاية وفعال للغاية ومحترف للغاية "
شهادات العملاء 2
رانجيث بالا
مستورد المنتجات الطبية من الهند
" نحن شركة لديها أكثر من 15 عامًا من الخبرة في العمل مع المؤسسات الخاصة والقطاعات الخاصة، وقد تعاونا مع شركة هيسو لمدة 3 سنوات، ونحن ممتنون حقًا للأعمال التي قدمتها لنا شركة هيسو. نحن ممتنون للتعاون مع شيري والسيد لي "
شهادات العملاء
هيرينا
المستشفيات والمورد الحكومي من رومانيا

انضم إلى الرواد العالميين الذين يعتمدون على خبرتنا في حلول تنقية الهواء.

استفسارك يهمنا. سنتصل بك قريباً، وستظل بياناتك آمنة دائماً.
لقد تعاونا مع هيسو لمدة 3 سنوات، ونحن ممتنون حقًا للأعمال التي قدمها لنا هيسو. نحن ممتنون للتعاون مع شيري والسيد لي.
TMS 1
توماس
مورد حكومي من ألمانيا
Contaminant Engineering•3 min read

PFAS Water Filtration Technologies Explained: Carbon, Resin & RO

Key Takeaway:

PFAS reduction depends on the specific compounds present, treatment media, contact time, water chemistry, and system design. Activated carbon, ion exchange, and Reverse Osmosis address PFAS through different mechanisms.

PFAS are a large family of persistent fluorinated compounds that can occur in drinking-water supplies. Their treatment behavior varies significantly by molecular structure, chain length, functional group, concentration, and the chemistry of the source water.

Granular Activated Carbon (GAC) removes PFAS primarily through adsorption. It is generally more effective for many longer-chain PFAS, while shorter-chain compounds tend to break through more quickly. Carbon performance depends on media properties, Empty Bed Contact Time (EBCT), competing organic matter, loading, and replacement frequency.

Ion-exchange resins use charged functional sites to capture many PFAS compounds. Properly selected anion-exchange media can provide high capacity and may perform better than conventional activated carbon for some shorter-chain PFAS, although performance still depends on water chemistry and competing ions.

Reverse Osmosis (RO) uses membrane separation rather than adsorption. Properly designed RO systems can provide broad reduction across many PFAS compounds as well as dissolved salts and other contaminants. Unlike carbon or resin, however, RO also produces a concentrate stream that must be managed.

No single technology should be selected from a PFAS label alone. System design should consider which PFAS compounds are present, their concentrations, required reduction targets, flow rate, media life, and the applicable third-party certification or validation requirements.

HisoAir Water Technical Series
Product Discovery•3 min read

How to Choose an Under-Sink Water Purifier for Modern Kitchens

Key Takeaway:

Match the treatment technology to your water quality first, then evaluate cabinet space, faucet configuration, flow rate, drain and power requirements, and filter replacement needs.

Choosing an under-sink water purifier starts with water chemistry. Carbon filtration is well suited to chlorine, taste, odor, and many organic contaminants, while Reverse Osmosis is more appropriate when dissolved salts, fluoride, nitrates, or broader dissolved contaminants need to be reduced.

For compact kitchens, tankless RO systems eliminate the conventional storage tank and can significantly reduce the space required under the sink. However, membrane capacity stated in GPD does not directly equal faucet flow. When comparing systems, check the actual dispensing flow rate, inlet-pressure requirement, recovery ratio, and whether a booster pump is required.

Installation architecture also matters. Many RO systems require a drain connection, electrical power, and either a dedicated drinking-water faucet or a compatible multi-function faucet. High-flow carbon systems can often connect directly to the existing cold-water line with a simpler installation, but pressure drop and available faucet flow should still be verified.

RO also removes much of the naturally occurring dissolved mineral content. Where taste or mineral balance is a priority, a post-RO remineralization stage can be added. Filter life should be evaluated by both rated capacity and local water quality rather than replacement time alone.

The right system is therefore not simply the smallest or highest-GPD model. It is the configuration that matches the target contaminants, available cabinet space, desired faucet setup, peak dispensing demand, and maintenance expectations.

HisoAir Water Technical Series
Water Quality•2 min read

What Does TDS Mean in Drinking Water? Measurement vs Contaminant Reality

Key Takeaway:

A TDS meter estimates the overall concentration of dissolved ionic substances from electrical conductivity. It cannot identify specific contaminants or determine whether water is chemically safe.

Total Dissolved Solids (TDS) refers to the combined concentration of dissolved substances in water. Most handheld TDS meters do not measure TDS directly. Instead, they measure electrical conductivity (EC) and convert that reading into an estimated parts-per-million (ppm) value.

This means a TDS reading can indicate how much dissolved ionic material is present, but not what that material actually is. Calcium, magnesium, sodium, nitrates, and other dissolved ions can all contribute to conductivity, yet a simple TDS meter cannot distinguish between them.

TDS meters are also not suitable for detecting trace contaminants such as PFAS, many VOCs, pesticides, pharmaceuticals, or disinfection byproducts. These substances may be present at concentrations far below the level needed to noticeably change electrical conductivity.

A low TDS reading therefore does not guarantee safe drinking water, and a higher TDS reading does not automatically indicate contamination. Water-treatment decisions should be based on laboratory testing for specific contaminants of concern rather than TDS alone.

HisoAir Water Technical Series
Technology Selection•2 min read

RO vs UF Water Filtration: Understanding Pore Sizes & Dissolved Minerals

Key Takeaway:

Ultrafiltration can reduce bacteria, turbidity, and suspended particles while retaining most naturally occurring dissolved minerals. Reverse Osmosis provides much broader reduction of dissolved salts and smaller contaminants.

Ultrafiltration (UF) typically uses hollow-fiber membranes with pore sizes in the approximate 0.01–0.1 micron range. These membranes physically retain turbidity, suspended solids, colloids, and many microorganisms while allowing dissolved minerals and salts to remain in the water.

Reverse Osmosis (RO) operates at a much finer separation level. Unlike UF, RO can substantially reduce dissolved ions such as sodium, calcium, fluoride, nitrates, and other contributors to total dissolved solids (TDS). This makes RO more suitable when dissolved-salt reduction is a primary treatment objective.

UF generally requires less system pressure and produces little or no continuous concentrate stream in many point-of-use configurations. RO typically requires greater pressure and produces a reject-water stream, but delivers broader contaminant reduction.

For water with acceptable TDS and mineral content, UF can be a simpler mineral-retaining treatment option. Where dissolved salts, fluoride, nitrates, or broader dissolved contaminants are a concern, RO is generally the more appropriate technology.

HisoAir Water Technical Series
Technology Selection•4 min read

Carbon Block vs Reverse Osmosis: Which Fits Your Need?

Key Takeaway:

Choose RO for dissolved inorganic salts and heavy metals; choose Carbon Block for chemical taste/odor, no wastewater, and high line-pressure flow.

Reverse Osmosis (RO) and Carbon Block filtration represent two fundamentally different treatment methods: membrane separation and adsorption. Understanding these differences helps determine which technology is better suited to a specific water-quality requirement.

Reverse Osmosis uses a semi-permeable membrane with pore sizes of approximately 0.0001 microns. It can significantly reduce dissolved inorganic contaminants such as TDS, fluoride, nitrates, and certain heavy metals. Because water must be forced through the membrane, RO systems require sufficient pressure or a booster pump and generate a concentrated wastewater stream.

Carbon Block filtration relies primarily on adsorption through compressed activated carbon, commonly with nominal pore sizes around 0.5–5 microns. It is highly effective for chlorine, chloramines, VOCs, taste, and odor, while allowing substantially higher direct-flow rates without producing wastewater.

From an operating perspective, Carbon Block systems are generally simpler, require less energy, and avoid the water loss associated with RO. RO involves higher system complexity and operating cost, but provides substantially broader reduction of dissolved contaminants that Carbon Block alone cannot address.

HisoAir Water Technical Series

طلب عرض أسعار